HP 5400 zl Switch Series
Layer 2/3/4 switches which support integrated advanced capabilities in chassis (6-slot and 12-slot) form factor
HP 5400R zl2 Series is now the Aruba 5400R Switch Series
More pricing below, click here!
Overview:
The HP 5400 zl Switch Series consists of advanced intelligent switches in the HP modular chassis product line, which includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for the switch series is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With 10/100, Gigabit Ethernet, and 10 Gigabit Ethernet interfaces; choice of PoE+ and non-PoE; integrated Layer 3 features; and HP AllianceONE solutions, the 5400 zl switch series offers excellent investment protection, flexibility, and scalability, as well as ease of deployment, operation, and maintenance.
- Advanced access layer, distribution, and core
- Integrated L2 to L4 intelligent edge feature set
- Enterprise-class performance and security
- HP AllianceONE integrated
- Scalable 10/100/1000 and 10 GbE connectivity
Features & Benefits:
Software-defined networking
- NEW OpenFlow — is a key technology that enables software-defined networking by allowing the separation of data (packet forwarding) and control (routing decision) paths
Quality of Service (QoS)
- Advanced classifier-based QoS — classifies traffic using multiple match criteria based on Layer 2, 3, and 4 information; applies QoS policies such as setting priority level and rate limit to selected traffic on a per-port or per-VLAN basis
- Layer 4 prioritization — enables prioritization based on TCP/UDP port numbers
- Traffic prioritization — allows real-time traffic classification into eight priority levels mapped to eight queues
- Bandwidth shaping —
- Port-based rate limiting — provides per-port ingress-/egress-enforced increased bandwidth
- Classifier-based rate limiting — uses an access control list (ACL) to enforce increased bandwidth for ingress traffic on each port
- Reduced bandwidth — provides per-port, per-queue egress-based reduced bandwidth
- Class of Service (CoS) — sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ
- Remote intelligent mirroring — mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or remote HP 8200 zl, 6600, 6200 yl, 5400 zl, or 3500 Switch located anywhere on the network
- RMON, XRMON, and sFlow v5 — provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
- IEEE 802.1AB Link Layer Discovery Protocol (LLDP) — advertises and receives management information from adjacent devices on a network, facilitating easy mapping by network management applications
- Uni-Directional Link Detection (UDLD) — monitors a cable between two switches and shuts down the ports on both ends if the cable is broken, turning the bidirectional link into a unidirectional one; this prevents network problems such as loops
- Management simplicity — provides common software features and CLI implementation across all HP ProVision-based switches (including the zl and yl switches)
- Command authorization — leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; an audit trail documents activity
- Friendly port names — allow assignment of descriptive names to ports
- Dual flash images — provide independent primary and secondary operating system files for backup while upgrading
- Multiple configuration files — can be stored to the flash image
- NEW Comware CLI —
- Comware-compatible CLI — bridges the experience of HP Comware CLI users who are using the HP ProVision software CLI
- Display and fundamental Comware CLI commands — are embedded in the switch CLI as native commands; display output is formatted as on Comware-based switches, and fundamental commands provide a Comware-familiar initial switch setup
- Configuration Comware CLI commands — when Comware commands are entered, CLI help is elicited to formulate the correct ProVision software CLI command
Connectivity
- IEEE 802.3az Energy Efficient Ethernet — lowers power consumption in periods of low link usage (supported on v2 zl 10/100/1000 and 10/100 modules)
- IEEE 802.3af Power over Ethernet (PoE) — provides up to 15.4 W per port to IEEE 802.3af-compliant PoE-powered devices such as IP phones, wireless access points, and security cameras
- IEEE 802.3at Power over Ethernet Plus — provides up to 30 W per port to IEEE 802.3 for PoE-/PoE+-powered devices such as video IP phones, IEEE 802.11n wireless access points, and advanced pan/zoom/tilt security cameras
- Prestandard PoE support — detects and provides power to prestandard PoE devices; see the list of supported devices in the product FAQ at www.hp.com/networking
- High-density port connectivity — provides up to 12 interface module slots and up to 288 wire-speed 10/100/1000 PoE-enabled ports or 96 10-GbE ports per system
- Jumbo frames — on Gigabit Ethernet and 10-Gigabit Ethernet ports, jumbo frames allow high-performance remote backup and disaster-recovery services
- Auto-MDIX — automatically adjusts for straight-through or crossover cables on all 10/100 and 10/100/1000 ports
- IPv6 —
- IPv6 host — enables switches to be managed in an IPv6 network
- Dual stack (IPv4 and IPv6) — transitions from IPv4 to IPv6, supporting connectivity for both protocols
- MLD snooping — forwards IPv6 multicast traffic to the appropriate interface
- IPv6 ACL/QoS — supports ACL and QoS for IPv6 network traffic
- IPv6 routing — supports static and OSPFv3 routing protocols
- 6in4 tunneling — supports encapsulation of IPv6 traffic in IPv4 packets
Performance
- High-speed, high-capacity architecture — 1 Tbps crossbar switching fabric provides intra-module and inter-module switching with 585.6 million pps throughput on the purpose-built ProVision ASICs
- Selectable queue configurations — allows for increased performance by selecting the number of queues and associated memory buffering that best meet the requirements of the network applications
Resiliency and high availability
- Virtual Router Redundancy Protocol — allows groups of two routers to dynamically back each other up to create highly available routed environments
- IEEE 802.1s Multiple Spanning Tree Protocol — provides high link availability in multiple VLAN environments by allowing multiple spanning trees; encompasses IEEE 802.1D Spanning Tree Protocol and IEEE 802.1w Rapid Spanning Tree Protocol
- IEEE 802.3ad Link Aggregation Control Protocol (LACP) and HP port trunking — support up to 144 trunks, each with up to eight links (ports) per trunk
- Distributed trunking — enables loop-free and redundant network topology without using Spanning Tree Protocol; allows a server or switch to connect to two switches using one logical trunk for redundancy and load sharing
- Optional redundant power supply (HP 5400 series) — provides uninterrupted power and allows hot-swapping of the redundant power supplies when installed
- Hot-swappable modules (5400 zl series) — permits modules, mini-GBICs, and power supplies in a redundant power supply configuration to be added or swapped without interrupting the network
- Sparing simplicity — HP zl-common accessories (interface modules and power supplies)
- Uplink Failure Detection — provides active-standby network path redundancy for servers that are configured for active-standby NIC teaming
Layer 2 switching
- VLAN support and tagging — supports the IEEE 802.1Q standard and 2,048 VLANs simultaneously
- IEEE 802.1v protocol VLANs — isolate select non-IPv4 protocols automatically into their own VLANs
- GARP VLAN Registration Protocol — allows automatic learning and dynamic assignment of VLANs
- IEEE 802.1ad Q-in-Q — increases the scalability of an Ethernet network by providing a hierarchical structure; connects multiple LANs on a high-speed campus or metro network
- MAC-based VLAN — provides granular control and security; uses RADIUS to map a MAC address/user to specific VLANs (requires v2 modules)
- Rapid Per-VLAN Spanning Tree (RPVST+) — allows each VLAN to build a separate spanning tree to improve link bandwidth usage; is compatible with PVST+
- HP switch meshing — dynamically load balances across multiple active redundant links to increase available aggregate bandwidth; allows concurrent Layer 3 routing with v2 modules
Layer 3 services
- User Datagram Protocol (UDP) helper function — allows UDP broadcasts to be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevents server spoofing for UDP services such as DHCP
- Loopback interface address — defines an address in Routing Information Protocol (RIP) and Open Standard Path First (OSPF), improving diagnostic capability
- Route maps — provide more control during route redistribution; allow filtering and altering of route metrics
- Static IP routing — provides manually configured routing for both IPv4 and IPv6 networks
- Routing Information Protocol (RIP) — provides RIPv1 and RIPv2 routing
- OSPF — provides OSPFv2 for IPv4 routing and OSPFv3 for IPv6 routing
- Policy-based routing — uses a classifier to select traffic that can be forwarded based on policy set by the network administrator (requires v2 modules)
- Border Gateway Protocol (BGP) — provides IPv4 Border Gateway Protocol routing, which is scalable, robust, and flexible
Security
- Access control lists (ACLs) — provide filtering based on the IP field, source/destination IP address/subnet, and source/destination TCP/UDP port number on a per-VLAN or per-port basis
- Multiple user authentication methods —
- IEEE 802.1X users per port — provides authentication of multiple IEEE 802.1X users per port
- Web-based authentication — authenticates from a Web browser for clients that do not support IEEE 802.1X supplicant
- MAC-based authentication — client is authenticated with the RADIUS server based on the client's MAC address
- Concurrent IEEE 802.1X, Web, and MAC authentication schemes per port — switch port accepts up to 32 sessions of IEEE 802.1X, Web, and MAC authentications
- Virus throttling — detects traffic patterns typical of worm-type viruses and either throttles or entirely prevents the virus from spreading across the routed VLANs or bridged interfaces without requiring external appliances
- DHCP protection — blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
- Secure management access — securely encrypts all access methods (CLI, GUI, or MIB) through SSHv2, SSL, and/or SNMPv3
- USB Secure Autorun (requires HP PCM+) — deploys, diagnoses, and updates a switch using a USB flash drive; works with a secure credential to prevent tampering
- Switch CPU protection — provides automatic protection against malicious network traffic trying to shut down the switch
- ICMP throttling — defeats ICMP denial-of-service attacks by enabling any switch port to automatically throttle ICMP traffic
- Identity-driven ACL — enables implementation of a highly granular and flexible access security policy and VLAN assignment specific to each authenticated network user
- STP BPDU port protection — blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged BPDU attacks
- Dynamic IP lockdown — works with DHCP protection to block traffic from unauthorized hosts, preventing IP source address spoofing
- Dynamic ARP protection — blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
- STP Root Guard — protects the root bridge from malicious attacks or configuration mistakes
- Detection of malicious attacks — monitors 10 types of network traffic and sends a warning when an anomaly that potentially can be caused by malicious attacks is detected
- Port security — allows access only to specified MAC addresses, which can be learned or specified by the administrator
- MAC address lockout — prevents particular configured MAC addresses from connecting to the network
- Source-port filtering — allows only specified ports to communicate with each other
- RADIUS/TACACS+ — eases switch management security administration by using a password authentication server
- Secure shell — encrypts all transmitted data for secure remote CLI access over IP networks
- Secure Sockets Layer (SSL) — encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the switch
- Secure FTP — allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of a switch configuration file
- Management Interface Wizard — helps secure management interfaces such as SNMP, telnet, SSH, SSL, Web, and USB at the desired level
- Switch management logon security — helps secure switch CLI logon by optionally requiring either RADIUS or TACACS+ authentication
- Security banner — displays a customized security policy when users log in to the switch
Convergence
- IP multicast routing — includes PIM Sparse and Dense modes to route IP multicast traffic
- IP multicast snooping (data-driven IGMP) — automatically prevents flooding of IP multicast traffic
- LLDP-MED (Media Endpoint Discovery) — is a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones
- PoE allocations — support multiple methods (automatic, IEEE 802.3af class, LLDP-MED, or user specified) to allocate PoE power for more efficient energy savings
- Auto VLAN configuration for voice —
- RADIUS VLAN — uses a standard RADIUS attribute and LLDP-MED to automatically configure a VLAN for IP phones
- CDPv2 — uses CDPv2 to configure legacy IP phones
- RADIUS VLAN — uses a standard RADIUS attribute and LLDP-MED to automatically configure a VLAN for IP phones
- CDPv2 — uses CDPv2 to configure legacy IP phones
Warranty and support
- Lifetime warranty — for as long as you own the product with advance replacement and next-business-day delivery (available in most countries)†
- Electronic and telephone support — limited electronic and telephone support is available from HP; to reach our support centers, refer to www.hp.com/networking/contact-support; for details on the duration of support provided with your product purchase, refer to www.hp.com/networking/warrantysummary
- Software releases — to find software for your product, refer to www.hp.com/networking/support; for details on the software releases available with your product purchase, refer to www.hp.com/networking/warrantysummary
Specifications:
5406 | 5412 | 5406-44G-PoE+-2XG v2 | |
---|---|---|---|
Part Number | HP 5406 zl Switch with Premium Software (J9642A) | HP 5412 zl Switch with Premium Software (J9643A) | HP 5406-44G-PoE+-2XG v2 zl Switch with Premium Software (J9533A) |
Included accessories | |||
1 HP 5400 zl Premium License (J8994A) | 1 HP 5400 zl Premium License (J8994A) | 1 HP 20-port Gig-T PoE+ / 2-port 10GbE SFP+ v2 zl Module (J9536A) 1 HP 1500W PoE+ zl Power Supply (J9306A) 1 HP 24-port Gig-T PoE+ v2 zl Module (J9534A) 1 HP 5400 zl Premium License (J8994A) |
|
Ports | |||
6 open module slots Supports a maximum of 48 10GbE ports or 144 autosensing 10/100/1000 ports or 144 mini-GBICs, or a combination |
12 open module slots Supports a maximum of 96 10GbE ports or 288 autosensing 10/100/1000 ports or 288 mini-GBICs, or a combination |
44 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+) Media Type: Auto-MDIX Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 2 open 10GbE SFP+ transceiver slots 4 open module slots Supports a maximum of 16 10GbE ports or 140 autosensing 10/100/1000 ports or 100 mini-GBICs, or a combination |
|
Power supplies | |||
2 power supply slots 1 minimum power supply required (ordered separately) |
4 power supply slots 2 minimum power supplies required (ordered separately) |
2 power supply slots 1 minimum power supply required includes: 1 x J9306A (HP 1500W PoE+ zl Power Supply) |
|
Physical characteristics | |||
17.5(w) x 17.75(d) x 6.9(h) in (44.45 x 45.09 x 17.53 cm) (4U height) | 17.5(w) x 17.75(d) x 12.1(h) in (44.45 x 45.09 x 30.73 cm) (7U height) | 17.5(w) x 17.75(d) x 6.9(h) in (44.45 x 45.09 x 17.53 cm) (4U height) | |
Weight | 23.55 lb (10.68 kg) | 34.94 lb (15.85 kg) | 46.08 lb (20.9 kg) |
Memory and processor | |||
Gigabit module | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM |
10G module | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM |
Management module | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM |
Mounting | |||
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | |
Performance | |||
1000 Mb Latency | < 3.7 µs (FIFO 64-byte packets) | < 3.7 µs (FIFO 64-byte packets) | < 3.7 µs (FIFO 64-byte packets) |
10 Gbps Latency | < 2.1 µs (FIFO 64-byte packets) | < 2.1 µs (FIFO 64-byte packets) | < 2.1 µs (FIFO 64-byte packets) |
Throughput | up to 282.1 million pps | up to 564.2 million pps | up to 282.1 million pps |
Routing/Switching capacity | 379.2 Gbps | 758.4 Gbps | 379.2 Gbps |
Switch fabric speed | 379.2 Gbps | 758.4 Gbps | 379.2 Gbps |
Routing table size | 10000 entries (IPv4) | 10000 entries (IPv4) | 10000 entries (IPv4) |
MAC address table size | 64000 entries | 64000 entries | 64000 entries |
Environment | |||
Operating temperature | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed |
Operating relative humidity | 15% to 95% @ 131°F (55°C), noncondensing | 15% to 95% @ 131°F (55°C), noncondensing | 15% to 95% @ 131°F (55°C), noncondensing |
Nonoperating/Storage temperature | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) |
Nonoperating/Storage relative humidity | 15% to 95% @ 149°F (65°C), noncondensing | 15% to 95% @ 149°F (65°C), noncondensing | 15% to 95% @ 149°F (65°C), noncondensing |
Altitude | up to 10,000 ft (3 km) | up to 10,000 ft (3 km) | up to 10,000 ft (3 km) |
Acoustic | Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296 | Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO 9296 | Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296 |
Electrical characteristics | |||
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Achieved Miercom Certified Green Award | |||
Description | Chassis ships without power supplies. Two power supply slots are available; three different power supplies are available. See power supply products for additional specifications. | Chassis ships without power supplies. Four power supply slots are available; three different power supplies are available. See power supply products for additional specifications. | One J9306A product is installed. One open power supply slot is available; three different power supplies are available. See power supply products for additional specifications. |
Maximum heat dissipation | 2450 BTU/hr (2584 kJ/hr), (max. non-PoE); 3700 BTU/hr (3903 kJ/hr) (max. using PoE) | 4900 BTU/hr (5169 kJ/hr), (max. non-PoE); 7400 BTU/hr (7,807 kJ/hr) (max. using PoE) | 2450 BTU/hr (2584.75 kJ/hr), (max. non-PoE); 3700 BTU/hr (3903 kJ/hr) (max. using PoE) |
Voltage | 100-127/200-240 VAC | 100-127/200-240 VAC | 110-127/200-240 VAC |
Idle power | 215 W | ||
Notes | Power supplies must be ordered separately. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. | Power supplies must be ordered separately. Two power supplies are required to power the J8698A chassis. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. | Idle power is the actual power consumption of the device with no ports connected. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. |
Safety | |||
CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | |
Notes | |||
Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). | Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). | Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). |
5412-92G-PoE+-2XG v2 | 5406-44G-PoE+-4G-SFP v2 | 5412-92G-PoE+-4G v2 | |
---|---|---|---|
Part Number | HP 5412-92G-PoE+-2XG v2 zl Switch with Premium Software (J9532A) | HP 5406-44G-PoE+-4G-SFP v2 zl Switch with Premium Software (J9539A) | HP 5412-92G-PoE+-4G v2 zl Switch with Premium Software (J9540A) |
Included accessories | |||
3 HP 24-port Gig-T PoE+ v2 zl Module (J9534A) 1 HP 20-port Gig-T PoE+ / 2-port 10GbE SFP+ v2 zl Module (J9536A) 2 HP 1500W PoE+ zl Power Supply (J9306A) 1 HP 5400 zl Premium License (J8994A) |
1 HP 24-port Gig-T PoE+ v2 zl Module (J9534A) 1 HP 20-port Gig-T PoE+ / 4-port SFP v2 zl Module (J9535A) 1 HP 1500W PoE+ zl Power Supply (J9306A) 1 HP 5400 zl Premium License (J8994A) |
3 HP 24-port Gig-T PoE+ v2 zl Module (J9534A) 1 HP 20-port Gig-T PoE+ / 4-port SFP v2 zl Module (J9535A) 2 HP 1500W PoE+ zl Power Supply (J9306A) 1 HP 5400 zl Premium License (J8994A) |
|
Ports | |||
92 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+) Media Type: Auto-MDIX Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 2 open 10GbE SFP+ transceiver slots 8 open module slots Supports a maximum of 32 10GbE ports or 284 autosensing 10/100/1000 ports or 196 mini-GBICs, or a combination |
44 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) Media Type: Auto-MDIX Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 open mini-GBIC slots 4 open module slots Supports a maximum of 16 10GbE ports or 140 autosensing 10/100/1000 ports or 100 mini-GBICs, or a combination |
92 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+) Media Type: Auto-MDIX Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only 4 open mini-GBIC slots 8 open module slots Supports a maximum of 32 10GbE ports or 284 autosensing 10/100/1000 ports or 196 mini-GBICs, or a combination> |
|
Power supplies | |||
4 power supply slots 2 minimum power supplies required includes: 2 x J9306A (HP 1500W PoE+ zl Power Supply) |
2 power supply slots 1 minimum power supply required includes: 1 x J9306A (HP 1500W PoE+ zl Power Supply) |
4 power supply slots 2 minimum power supplies required includes: 2 x J9306A (HP 1500W PoE+ zl Power Supply) |
|
Physical characteristics | |||
17.5(w) x 17.75(d) x 12.1(h) in (44.45 x 45.09 x 30.73 cm) (7U height) | 17.5(w) x 17.75(d) x 6.9(h) in (44.45 x 45.09 x 17.53 cm) (4U height) | 17.5(w) x 17.75(d) x 12.1(h) in (44.45 x 45.09 x 30.73 cm) (7U height) | |
Weight | 75.36 lb (34.18 kg) | 45.58 lb (20.68 kg) | 74.86 lb (33.96 kg) |
Memory and processor | |||
Gigabit module | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM |
10G module | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM | ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM |
Management module | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM | Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM |
Mounting | |||
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only | |
Performance | |||
1000 Mb Latency | < 3.7 µs (FIFO 64-byte packets) | < 3.7 µs (FIFO 64-byte packets) | < 3.7 µs (FIFO 64-byte packets) |
10 Gbps Latency | < 2.1 µs (FIFO 64-byte packets) | < 2.1 µs (FIFO 64-byte packets) | < 2.1 µs (FIFO 64-byte packets) |
Throughput | up to 564.2 million pps | up to 282.1 million pps | up to 564.2 million pps |
Routing/Switching capacity | 758.4 Gbps | 379.2 Gbps | 758.4 Gbps |
Switch fabric speed | 758.4 Gbps | 379.2 Gbps | 758.4 Gbps |
Routing table size | 10000 entries (IPv4) | 10000 entries (IPv4) | 10000 entries (IPv4) |
MAC address table size | 64000 entries | 64000 entries | 64000 entries |
Environment | |||
Operating temperature | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed | 32°F to 131°F (0°C to 55°C); 0°C to 40°C with J8706A or J8707A modules installed |
Operating relative humidity | 15% to 95% @ 131°F (55°C), noncondensing | 15% to 95% @ 131°F (55°C), noncondensing | 15% to 95% @ 131°F (55°C), noncondensing |
Nonoperating/Storage temperature | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) |
Nonoperating/Storage relative humidity | 15% to 95% @ 149°F (65°C), noncondensing | 15% to 95% @ 149°F (65°C), noncondensing | 15% to 95% @ 149°F (65°C), noncondensing |
Altitude | up to 10,000 ft (3 km) | up to 10,000 ft (3 km) | up to 10,000 ft (3 km) |
Acoustic | Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO 9296 | Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296 | Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO 9296 |
Electrical characteristics | |||
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Description | Two J9306A products are installed. Two open power supply slots are available; three different power supplies are available. See power supply products for additional specifications. | One J9306A product is installed. One open power supply slot is available; three different power supplies are available. See power supply products for additional specifications. | Two J9306A products are installed. Two open power supply slots are available; three different power supplies are available. See power supply products for additional specifications. |
Maximum heat dissipation | 4900 BTU/hr (5169.5 kJ/hr), (max. non-PoE); 7400 BTU/hr (7807 kJ/hr) (max. using PoE) | 2450 BTU/hr (2584.75 kJ/hr), (max. non-PoE); 3700 BTU/hr (3903 kJ/hr) (max. using PoE) | 4900 BTU/hr (5169.5 kJ/hr), (max. non-PoE); 7400 BTU/hr (7807 kJ/hr) (max. using PoE) |
Voltage | 110-127/200-240 VAC | 110-127/200-240 VAC | 110-127/200-240 VAC |
Idle power | 312 W | 215 W | 312 W |
Notes | Idle power is the actual power consumption of the device with no ports connected. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. |
Idle power is the actual power consumption of the device with no ports connected. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. |
Idle power is the actual power consumption of the device with no ports connected. Heat dissipation does not include heat dissipated by the PoE-powered devices themselves. |
Safety | |||
CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 | |
Notes | |||
Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). | Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). | Supported 1G SFP transceivers are revision "B" or later (product number ends with the letter "B" or later; for example, J9142B, J8177C). |
Documentation:
Download the HP 5400 zl Switch Series Datasheet (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.